Coax
Cable Signal Loss (Attenuation) in dB per 100ft* |
||||||||
|
Loss* |
||||||||
|
1MHz |
1.9dB |
0.4dB |
0.5dB |
0.2dB |
0.2dB |
0.2dB |
0.3dB |
0.2dB |
|
10MHz |
3.3dB |
1.4dB |
1.0dB |
0.6dB |
0.6dB |
0.4dB |
0.5dB |
0.4dB |
|
50MHz |
6.6dB |
3.3dB |
2.5dB |
1.6dB |
1.4dB |
1.0dB |
1.1dB |
0.9dB |
|
100MHz |
8.9dB |
4.9dB |
3.6dB |
2.2dB |
2.0dB |
1.6dB |
1.5dB |
1.4dB |
|
200MHz |
11.9dB |
7.3dB |
5.4dB |
3.3dB |
2.8dB |
2.3dB |
2.0dB |
1.8dB |
|
400MHz |
17.3
B |
11.2dB |
7.9dB |
4.8dB |
4.3dB |
3.5dB |
2.9dB |
2.6dB |
|
700MHz |
26.0dB |
16.9dB |
11.0dB |
6.6dB |
5.6dB |
4.7dB |
3.8dB |
3.6dB |
|
900MHz |
27.9
B |
20.1dB |
12.6dB |
7.7dB |
6.0dB |
5.4dB |
4.9dB |
4.2dB |
|
1GHz |
32.0dB |
21.5dB |
13.5dB |
8.3dB |
6.1dB |
5.6dB |
5.3dB |
4.5dB |
|
Imped |
50ohm |
50ohm |
50ohm |
50ohm |
75ohm |
75ohm |
50ohm |
50ohm |
|
* Note: Coax losses
shown above are for 100 feet lengths. Loss is a length multiplier, so a 200
ft length would have twice the loss shown above and a 50 ft length would have
half the loss. This multiplier factor is why you should keep cable
installation lengths between radios and antennas as short as practical! |
||||||||
dB
Loss Per 100-feet for Various Cables
|
Cable |
15
Mhz |
30
Mhz |
50
Mhz |
150
Mhz |
|
RG-58
foam |
1.5 |
2.15 |
2.75 |
4.7
|
|
RG-8
foam |
.62 |
.89 |
1.22 |
2.15
|
|
9913 |
.5 |
.72 |
.92 |
1.7
|
|
1/2"
75ohm hardline* |
.3 |
.45 |
.62 |
1.2
|
|
3/4"
75ohm hardline* |
.23 |
.35 |
.46 |
.87
|
|
450ohm
ladder line |
.01 |
.1 |
.135 |
.26 |
Actual Power Available at Far End of 100-foot Run
For 100 Watts In * 50 ohm has slightly less loss
|
Cable |
15
Mhz |
30
Mhz |
50
Mhz |
150
Mhz |
|
RG-58
foam |
71 |
62 |
54 |
33
|
|
RG-8
foam |
87 |
83 |
72 |
62
|
|
9913 |
90 |
84 |
83 |
67
|
|
1/2"
75ohm hardline* |
95 |
90 |
87 |
75
|
|
3/4"
75ohm hardline* |
95+ |
94 |
90 |
82
|
|
450ohm
ladder line |
100 |
98 |
97 |
95 |
One Mile of 450 ohm ladder
line has .53 dB loss at 15 Mhz
One Hundred Feet
of Belden 9913 has .5 dB loss at 15 Mhz